Wireless low strain pile integrity testing equipment is used to assess the integrity of concrete pile and identify the extent and location of the pile defect. It can be used for testing bored concrete pile and hammer pile, also be used for testing the constructions with an exposed top surface.
Chat Now

Product Details


Standard Components: 

1. Wireless Sensor.

2. Pad and charger.

3. Hammer Tools.



Technical Features:

1. Wireless connectivity between accelerated sensor and PDA allows easy and more flexible usage on site. PDA can work up to 10 meters away from the accelerated sensor.

2. Real time on-site processing such as smoothing, differential, filtering, exponent and linear amplification can be given to tested waveform.

3. The signal noise can be eliminated by taking average superposition of multiple signals. Superposition signals can be checked at any time, and poor-quality signals can be rejected.

4. Project/pile testing data can be easily saved, accessed, edited, or deleted.

5. Gain value can be adjusted according to length of pile and top surface condition of pile.

6. Intelligent sensor can complete the acquisition work, and upload the data to the computer through the Wi-Fi, get rid of signal wire entanglement, efficient, fast and smooth.

7. True 24 bit A/D data acquisition makes test waveform more real, avoiding the noise and signal distortion caused by floating point amplification.

8. New wavelet processing method can effectively judge the integrity of foundation pile in complex situation.



Technical Specifications:

Model: GDL-P8000

Control Mode: Android platform

Screen: High brightness, TFT color LCD screen

Data Storage: ≥8GB

Operation Mode: Touch screen

Sentinel magnify (time): 1、2、4、8、16、32 adjustable

A/D resolution (bit): 24 bits A/D

Sampling time intervals(μs): 6.4~1638.4 adjustable

Max length of sampling: ≥2048

Trigger: Signal trigger

Noise voltage of the system (mV): ≤2

Dynamic range(dB): ≥180

Amplifier frequency range(Hz): 1~10k

Max storage length: 2048

Amplitude nonlinear degree: ≤10%

Fixed point magnification: 1, 2, 4, 8, 16, 32,64

Error of time indication: ≤1%

Time resolution(us): 6.4

Gain error(dB): ≤1

Continuous working time(h): >5

Number of channels: 1

Interference between the channels: No

Transducer/Probe Sensitivity(acceleration mode)(mv/g): ≥100

Frequency range of Probe(Acceleration probe)(Hz): 0.5 ~ 9000

Power Internal: Built-in-battery; External: 220V AC/DC

Wi-Fi: Yes

Weight(kg): 0.34kg(lithium battery included)

Total volume(mm): φ5×120